Pages

Showing posts with label AV RECEIVERS. Show all posts
Showing posts with label AV RECEIVERS. Show all posts

Tuesday, June 28, 2016

ONKYO TX-NR1030 - AV Receiver - Service mode - Function checks - Idle current adjustments - Firmware update procedure - AV receiver Repair and service - Manual Tips

                                                 Category: AV Receiver Repair and Service 

Contents of this article 
  • Service mode access
  • Idle current setting 
  • Firmware Update 


ONKYO TX-NR1030

SERVICE INFORMATION MODE
Displaying Service information
This service information display system is helpful in analyze the status when the unit goes into Protect mode and is powered off
Pay attention that the status will change if a button is pushed.
1. Press twice the ON/STANDBY key while pressing the DISPLAY key.
The version of main microprocessor is displayed only for 3 seconds.
2. Press HOME button within 3 seconds above.
3. Press HOME button again. The following information are dispiayed.
01:23 10h + Information Dispiayed (Record this information)
4. Press ONISTANDBY button to exit the display of service information.
(Ref; Press RETURN button to initialize the data in the service information.)
NOTATION ABOUT ENTERING TEST MODE BY PRESSING BUTTON
In this procedure, the following notations are used to simplify explanation of how to press button.
e.g.-1 [TWCD] + [ONISTANDBY] --> [BDIDVD]
This means "While holding down TWCD button, press ONISTANDBY button then release both buttons and then press
BDIDVD button".
e.g.-2 [DISPLAY] + [ONISTANDBY] *2 _> [DIMMER]
This means "While holding down DISPLAY button, press ONKSTANDBY button twice then release both buttons and then press
DIMMER button".
INITIAL SETTING FOR SHIPPING
Initialization of memories.
Do the following operation.
[CBLISAT] + [ONISTANDBY]
Unplug the power cord from AVR after the FL tube displays "Clear" and AVR goes standby.
CONFIRMATION OF MAIN CHECKSUM
MAIN Checksum can be confirmed the following operation.
[DISPLAY] + [ON/STANDBY] * 2 Q [MEMORY]
CONFIRMATION OF OUTPUT VOLTAGE AND THERMAL SENSOR
Temperature and output voltage can be confirmed the following operation.
[DISPLAY] + [ONISTANDBY] * 2 >  [MEMORY
CONFIRMATION OF MODEL NAME AND DESTINATION
Model name and destination can be confirmed the following operation
[TVICD] + [ONISTANDBY] -> [DlMMER](RT!PTY!TP) -> [TONE+] *4
TEST MODE FOR OPERATION
Do the following operation.
1. Set the following VOL level.
VOL level : 30
2. [TWCD] + [ONISTANDBY]
CONFIRMATION OF VOLTAGE-DETECTION PROTECTORS.(The following model only)
Applied model TX-NR1 0301/3030, DTR-60.61"./0.6
<NOTE>
Don't connect load nor short speaker terminals.
1. Do the following operation.
1-1. set the volume level to 30
1-2. [TWCD] + [ONISTANDBY] --> [BDIDVD]
1-3. [TONE +]
to the following test mode.
TES T 1-01
2. AVR automatically tests in the following test sequence. And if it is all OK, Wi-Fi test will begin.
Test sequence
(FL+)-->(FR-)-->(C+)-->(SL-)-->(SR+)-->(SBL-)-->(SBR+)-->(FWL-)-->(FWR+)-->(FHL-)-->(FHR+)
3. If FL tube displays Wi-Fi check mode then voltage-detection protectors test will be completed.
CONFIRMATION OF UPDATE ROUTE.
1. Do the following operation.
1-1. set the volume level to 30
1-2. [FVICD] + [ONISTANDBY] --> [BDIDVD]
1-3. [TONE +]
to the following test mode.
TES T 1-01
2. Once the above mentioned test mode is entered, voltage-detection protectors function is checked automatically first, then update route check will begin.
If the result of update route check is no problem then Wi-Fi check will begin. If the result is NG then NG message will be shown on the FL tube.
3. If FL tube displays Wi-Fi check mode then voltage-detection protectors test and update route check are passed.
CONFIRMATION OF Wi-Fi CONNECTION (The following model only)
 Applied model TX-NR1030/3030,PR-SC5530
1. Setting Wi-Fi routers.
2. set the following test mode.
TEST 1-O1
3. Once the above mentioned test mode is entered, voltage-detection protectors function is checked automatically first, then update route check will begin and then Wi-Fi check will begin.
In Wi-Fi check mode, it connects an access point automatically. Wi-Fi LED flashes during connection.
4. If connection is completed and IP address is successfully acquired, Wi-Fi LED turning lights off and the value of RSSI to an access point is displayed in dBm.
If the connection is failed, NG is displayed.
In case value of RSSI level isn't showed on the FL tube at all past 4 minutes in this timer mode, judge as NG.
If the connection is failed, exit the idling timer mode by pressing the TWCD button and please try again from step-1.
CONFIRMATION OF CURRENT DETECTION PROTECTORS (The following model only)
Applied model ITX-NR1030/3030, DTR-60.6f70.6
1. Do the following operation.
1-1. set the volume level to 30
1-2. [TVICD] + [ONISTANDBY] -> [CBL.lSA‘l]
1-3. [TONE -]
to the following test mode.
TEST 1-0.9
2. Confirm that relay is not cut off even if you connect the following load A to the following channels one by one.
3. Confirm that relay is cut if you connect the following load B to the following channels one by one.
Channel FL, FR, C, SL, SR, SBL, SBR, LH, RH, LW ,RW ch LW ,RW ch : TX-NR3030, DTR-70.6 only
Load A 3 ohm
Load B 1 ohm
CONFIRMATION OF OUTPUT SENSOR
1. Do the following operation.
1-1. set the volume level to 30
1-2. [TVICD] + [ONISTANDBY] --> [CBL.lSA‘l]
1-3. [TONE - ] *2 and (*3)
to the following test mode.
TEST 1-07 and TEST 1-08
After lighting "FM STEREO" on the FL tube.
Relays RL6901, RL6902, RL6903, RL6904
CONFIRMATION OF COOLING FAN OPERATION
Applied model ITX-NR1030f3030, DTR-60.6f70.6
1. Confirm fan that is not rotating.
2. Set the following test mode and confirm fan that is rotating at HIGH speed.
TEST 1-07
3. Set the following test mode B and confirm fan that is rotating at LOW speed.
TEST 1-08
CONFIRMATION OF KEY OPERATION
1. Do the following operation.
1-1. set the volume level to 30
1-2. [TWCD] + [ONTSTANDBY] --> [CBLISAT]
1-3. [TONE - ] *4
to the following test mode.
TEST 1-06
2. Confirm each key and master volume operation.
3. If "ON,*'STANDBY" button is pressed, AVR escapes from this KEY test mode.
Therefor, press the "ONISTANDBY" button, after checking other buttons finished.
CONFIRMATION OF FL TUBE AND LED
1. Do the following operation.
[TVICD] + [ONISTANDBY] -> [DIMMER]
2. Confirm that all LEDs and all segments of FL tube are lit.
CONFIRMATION OF HEAD PHONE OPERATION
Confirm the headphone mark when headphones plug is inserted into the PHONES jack.
CONFIRMATION OF FM RADIO OPERATION
1. Setting of Signal Generator(SG)
Carrier frequency any
Modulation 1kHz
Deviation 75kHz
Output level 35dBu
2. Waveform confirmation
Set the signal of SG as following channels and confirm output is the following.
Output
Lch R ch
(1) R ch only No Yes
(2) L + R ch Yes Yes
3. Confirmation of Stereo indicator
Set SG as stereo and confirm stereo indicator is on.
SG Input
4. Confirmation of Auto stop operation
Do auto tuning (Press TUNING UP or TUNING DOWN button) and confirm that the searching stops when a station that is set by SG is found.
CONFIRMATION OF RDS (RADIO DATA SYSTEM) OPERATION (Applied to MPPIMPBIMM* type)
1 Input 98MHz,30dBp signal modulated with RDS data.
DS TEST" shall be displayed within 2 seconds
2. When a PS information is received, the name of the station "R
instead of the frequency.
CONFIRMATION OF OSD(ON SCREEN DISPLAY) OPERATION
1. When  HOME button is pushed confirm that setup menu is displayed in HDMI Out.
2. Confirm that specified operations for ENTER(with 4-cursor) buttons are made.
CONFIRMATION OF CEC OPERATION
1. Connect AVR's HDMI OUT to HDMI input of appliance compatible with CEC(SlNK or REPEATER] by HDMI cable.
2. Turn on the power to the AVR
3. Do the following operation.
3-1. set the volume level to 30
3-2. [TVICD] + [ONISTANDBY] --> [AUX]
to the following test mode.
TEST 6-00
FL tube will display "OK" or "NG".
CONFIRMATION OF DOLBY TEST TONE
1. Press TEST TONE on remote controller then press CH SELECT repeatedly.
Set turn to Dolby Test mode tone Check speaker condition.
2. Please check that a sound comes out from each channel.
--> FL ch -> C ch --> FR ch --> SR ch --> SBR ch --> SBL ch --> SL ch -> SW ch -->
CONFIRMATION OF FL DISPLAY
1. D0 the following operation.
1-1. set the volume level to 30
1-2. [TVICD] + [ONISTANDBY] ---> [DIMMER(RT/PTY/TP)]
to the F1. test mode
TONE+ = Step up
TONE- = Step down
The contents of the step are as follows.
1. Lit all segment and LED
2. Lit '23456789ABCDEF' and LED.
3. Lit a even number segment and LED.
4. Lit an odd number segment and LED.
5. The Destination setting is displayed and LED.
ADJUSTMENT OF IDLING CURRENT
Applied to the following model.
(Model  TX-NR1030/3030, DTR-60.6/70.6
Procedure
a. Pre-adjustment
Set the following registers to minimum position before POWER ON.
Set the voltages at the following terminals to the following voltage by adjusting the following registers, under the condition of no input and no load, immediately after POWER ON.
TX-NRSOSO, DTR-70.6
Channel L/C/R/ SL/SR/SBL/SBR/LH/RH/LW/RW
Check point(Terminals) P6070 -6080
Adjustment point (Registers) R6040>6049,R6360
Voltage 3.0mV
TX-NR1030, DTR-60.6
SL/SR/SBL/SBR/LH/RH
Check point(Terminals) P6070-P6078
Adjustment point (Registers) P6040----P6048
Voltage 3.0mV
Common adjustment for both models
b. Aging
Heat run during the following time.
Time 4>6 minutes
c. Final adjustment
Re-adjust by the following procedure after heat running for the above mentioned time.
L/C/R/SL/SR/SBL/SBR/LH/RH/LW/RW
Below 4mV  to 4mV
Between 4~6mV Do not adjust.
Over 6mV  to 6mV
FIRMWARE UPDATE
USB Update (service mode)
Preparation
1. Connect the USB storage device to your PC. If there is any data in the USB storage device, remove it.
2. Download the firmware file
3. Copy it to the USB storage device. Be careful not to copy the zip file
Overwriting is also possible.
1. Tum on the unit. It takes some time to start after you switch on the unit.
2. Select the USB input source.
3. Connect the USB storage device to USB port on the unit. Wait until Initializing of USB/N ET finishes
4. Hold down [DISPLAY] button and then press [ON/STANDBY] button twice.
Main version will be displayed, and HYBRID STANDBY indicator will start to flash.
5. Press [RETURN] button. “NET -> ALL_D" will be displayed.
6. Select “USB -> ALL_D" by [PRESET(left/right)] cursors and [TUNlNG(up/down)] cursors,
then press [ENTER] button, updating will begin.
7. Wait until update is completed. “Then the update ends, “Completed!” is displayed.
(If you leave it, it automatically turns standby mode. )
8. Press [ON/STANDBY] button, and the unit turns on.
9. Check the new FW version number.
Read more »

DENON HD AV Receiver - AVR 3311 - Version update - Factory reset - special mode procedures - Amplifier Idle current adjustments procedure - AV Receiver repair and service - Manual Tips

                                                Category: HD AV Receiver and Service 

Contents of this article 

  • Special mode setup
  • Micom Version udpdate
  • Idle current adjustment 

DENON AVR 3311

SERVICING
Before the Digital P.W.B. are replaced
If you cannot specify the cause of the digital PWB defect, carry out "Initializing" > "Update to latest firmware". The defect may be cleared.
# See the following for the method of initializing the Micom.
Initializing AV SURROUND RECEIVER
AV SURROUND RECEIVER initialization should be performed when the Micom, peripheral parts of Micom, and Digital P.W.B. are replaced.
1. Turn off the power using ON/STANDBY button.
2. Press ON/STANDBY button while simultaneously pressing STANDARD and DSP SIMULATION buttons.
3. Check that the entire display is flashing with an interval of about 1 second, and release your fingers from the 2 
buttons and the microprocessor will be initialized.
Service Jigs
When you repair the printing board, you can use the following JIG (Extension cable kit).
Please order to Denon Official Service Distributor in your region if necessary.
8U-110084S : EXTENSION UNIT KIT : 1 Set
SPECIAL MODE
Special mode setting button
 Press the ON/STANDBY button to turn on while pressing both buttons A and B at the same time.
Mode
Button A
Button B
Contents
Version display (Micom/DSP Error Display)
STATUS
RETURN
Serial No. and firmware versions such as Main, Sub, DSP are displayed in the FL manager. Errors are displayed when they occur.
Displaying the protection history mode
STATUS
MENU
Displaying the protection history
IInitialization mode (Remove settings for Installer Setup.)
STANDARD
DSP  SIMULATION
Backup (Remove data settings initialization for Installer is carried Setup) out.
Initialization mode (Includes settings for Installer Setup)
CURSOR UP
CURSOR DOWN
Backup (Includes data settings initialization for Installer is carried Setup) out.
Mode for switching tuner frequency step
STANDARD
DIRECT/ STEREO
---E2 model only--- Change tuner frequency step to FM:200kHz/AM:10kHzSTEP
Mode for preventing remote control acceptance
STATUS
ENTER
Operations using remote control are rejected. (Mode cancellation: Turn off power and execute the same button operations as when performing setup.)
Panel lock mode
DSP SIMULATION
DIRECT/ STEREO
Operations using main unit panel buttons or master volume are rejected.
Panel lock mode (Remove Master volume)
DIRECT/ STEREO
PURE DIRECT
Operations using main unit panel buttons are rejected.
Cancellation of panel lock mode
DIRECT/ STEREO
ENTER
Panel lock mode is cancelled.
Installer Setup mode
MENU
CURSOR LEFT
Access Remote Maintenance mode via the internet.Installer Setup is displayed on GUI/Option Menu. #Refer to AVR_RemoteMaintenance_.pdf of SDI.
Diagnostic mode
CURSOR LEFT
ENTER
This mode is used for confirming the Video and Audio (signal) paths. (Troubleshooting) Confirming the operation of unit can be easily done after repair.
NOTE:
If " S " is displayed on the fluorescent display, the unit is set to the special developer's mode and RS-232C
communications are not possible.
Press and hold in the "STATUS" and " DOWN " buttons for over 3 seconds with the power turned on to turn the " S "
display off. RS-232C communications are now enabled.
Micom/DSP Version display mode
Micom/DSP version display mode:
When started up, the version information is displayed.
Starting up:
With the "RETURN" and "STATUS" buttons pressed, press the "ON/STANDBY" button to turn the power on. Now, press the "STATUS" button to the display the 2nd item information on the FL Display.
Errors checking mode (Displaying the protection history)
Error mode (Displaying the protection history):
When started up, the error information is displayed.
Starting up:
All model commonness
With the "STATUS" and "MENU" buttons pressed, press the "ON/STANDBY" button to turn the power on. The error (protection history display) mode is set. Now, press the "STATUS" button to turn on the FL display.
DIAGNOSTIC MODE (Video/Audio (signal) path confirmation mode)
This mode is used for confirming the Video and Audio (signal) paths. (Troubleshooting) Confirming the operation of unit can be easily done after repair.
Backup data will not be lost.
Starting diagnostic mode
Press the "CURSOR LEFT" and "ENTER" botton while simulltaneously pressing those two bottons of this unit.
Q1, Q2 and Q3 are lit in FL display.
Canceling diagnostic mode
Turn off the power by pressing the ON/Standby botton.
VERSION UPGRADE PROCEDURE OF FIRMWARE
You can update by downloading the latest firmware from the Internet.
1. Connecting to the Network
(1) System Requirement
# Internet Connection by Broadband Circuit
# Modem
# Router
# Ethernet cable (CAT-5 or greater recommended)
Check for Update and Update
Check if the latest firmware exists. You can also check approximately how long it will take to complete an update.
(1) Press the MENU button on the remote control to display the GUI menu.
(2) Use the cursor buttons to select "Manual Setup" > "Option Setup" > "Firmware Update" > "Update Check".
(3) Press the ENTER buttom.
# The latest version of the firmware uploaded to the web is displayed.
# If the latest firmware version is on the web, proceed to (4).
# If the latest firmware is already installed, press the MENU button to close the menu.
(4) Use the cursor buttons to select "Update", then press the ENTER button.
# During update, the power indicator lights red and the GUI screen is shut down. And a rough remaining time is
indicated on the display.
# When updating is complete the power indicator lights green and normal status is resumed.
(5) Press the MENU button to close the menu.
Cautions on Firmware Update
# In order to use these functions, you must have the correct system requirements and settings for a broadband Internet connection.
#
Do not turn off the power until updating is completed.
Even with a broadband connection to the Internet, approximately about 1 hour is required for the updating procedure to be completed.
Once updating starts, normal operations on the AVR-3311 cannot be performed until updating is completed. Also, setting items of the GUI menu of AVR-3311 or setting items of the image adjustment may be initialized.
Make a note of the settings before updating, and set them again after updating
Idling Current
Required measurement equipment: DC Voltmeter
1. Preparation
(1) Avoid direct blow from an air conditioner or an electric fan, and adjust the unit at normal room temperature 15 °C ~ 30 °C (59 °F ~ 86 °F).
(2) Presetting
# POWER (Power source switch) STANDBY
# SPEAKER (Speaker terminal) No load
(Do not connect speaker, dummy resistor, etc.)
2. Adjustment
(1) Remove top cover and set VR401, VR402, VR403, VR404, VR405, VR406, VR407 on 7CH AMP UNIT at fully
counterclockwise position.
(2) Connect DC Voltmeter to test points (FRONT-Lch: TP401, FRONT-Rch: TP402, CENTER ch: TP403, SURROUNDLch: TP404, SURROUND-Rch: TP405, SURROUND-BACK Lch: TP406, SURROUND-BACK Rch: TP407.
(3) Connect power cord to AC Line, and turn power switch "ON".
(4) Presetting.
MASTER VOLUME : "---" counterclockwise (c min.)
SPEAKER (Speaker terminal) : No load
(Do not connect speaker, dummy resistor, etc.)
MODE : MCH STEREO
FUNCTION : DVD
(5) Within 2 minutes after the power on, turn VR401 clockwise to adjust the TEST POINT voltage to 8 mV ± 0.5 mV DC.
(6) After 10 minutes from the preset above, turn VR401 to set the voltage to 8 mV ± 0.5 mV DC.
(7) Adjust the Variable Resistors of other channels in the same way.
Read more »

Monday, June 27, 2016

ONKYO TX-NR545 AV Receiver - Factory reset procedure - Self diagnosis - Firmware checking and updating procedure - Troubleshooting - AV receiver Repair and service

                                                 Category: AV Receiver Repair and Service 

Contents of this article 
  • Factory Resetting Procedure
  • Firmware updating Procedure
  • Troubleshooting    

ONKYO TX-NR545

Resetting the Unit
# How to reset:
Step:1
While holding down CBUSAT on the main unit (note that step 2 must be performed with this button pressed down)
Step:2
Press ONISTANDBY on the main unit. ("Clear" appears on the display and the unit returns to standby.)
# Do not unplug the power cord until "Clear" disappears from the display.
# How to reset the remote controller:
Step:1
While holding down RECEIVER on the remote controller, press Q until the remote indicator stays lit (about 3 seconds).
Step:2
Within 30 seconds, press RECEIVER again.
Self-diagnostics
This function is For avoiding the rupture of electrolytic capacitors with amplifier circuit failure during power-ON.
Operation of Self—diagnostic
Self-diagnostic will start at the timing of next power on, after goes to the protect mode by Current detection or DC voltage detection.
Only On/Standby key could work in this mode. Also remote control does not work.
However, the CLEAR operation is enabled.
During Self-diagnostic, the power supply for amplifier circuit become low voltage state(SEC1-LOW), and the speaker relay will be turned off. Then, MPU will check each amplifier circuits internally by entering the test signal (20 kHz,-20 dBFS sine wave) to each channel from DSP.
MPU will judge the amplifier circuit is good or not from VOLH value.
The normal range of VOLH value is 0.04 V < VOLH < 0.20 V.
If VOLH value is in the out of this range, it will be judged as NG (No good).
No problem found
When protected by current detection, and no problem found, "CHECK SP WIRE“ will be displayed in this State, Only the On/Standby key is effective. And it do not anything for 3 minutes, unit goes into stand by automatically.
When protected by a DC voltage detection, and no problem found, unit goes into normal operation.
Problem found
When judged as there is a problem on any channel, the information of channel that has a problem will be displayed. In this State, Only the On/Standby key is effective. Also remote control does not work. if do not anything for 3 minutes, unit goes into standby automatically. This state will keep also after unit turn on/off, or AC unplugged.
The power supply for the amplifier becomes low voltage state and the speaker relay will be turned on.
Repair Process and How to Confirm
Confirmation of the protect cause
While NG channel is displayed, You can confirm the protect cause by following the step below
1. Press the Enter button
2. The protect cause are displayed for 5 seconds.
Please check the around of those amplifier circuit and repair it.
Clear of NG CH information
After repair, you can clear NG CH information by following the steps below.
1. Press the On!Standby key while pressing the Enter key.
2. Display as in the right figure appears.
3. Unit goes into Standby automatically after 5 seconds.
Self-diagnostic will start again at the timing of next power on.
By this, You can verify whether repair was properly or not.
If problem found after repair, please re-check the around of its circuit.
Cancel of Self-diagnostic
You can cancel this mode by clear operation (press Standby key while pressing CBL/SAT key)
After cancel this mode, receiver will be started as normal operation.
How to check Firmware Version & Preparation of Update
Step1 : [DISPLAY] + [ON/STANDBY] x 2
Main Firmware Version will appear on the main unit’s display.
Step2 : [TONE +]
NET Firmware Version will appear on the main unit’s display.
Step3 : [TONE +]
DSP Firmware Version will appear on the main unit's display.
Step4 : [TONE +]
VIDEO Firmware Version will appear on the main unit’s display.
Step5 : [TONE +]
OSD Firmware Version will appear on the main unit’s display.
Step6 : [TONE +]
V8100 Firmware Version will appear on the main unit’s display ( DTR-40.7 only)
Preparation of Update
1. Connect the USB storage device to your PC. If there is any data in the USB storage device, remove it.
2. Download the firmware file (package file) from the Onkyo FTP-server.
However European service partners should download the firmware file (package file) from the ExtraNet.
Onkyo FTP-server: onkyo.co.jpf_servicefwalTX-NR545
ID and Password are those we informed when changed.
Filename is as follows: ON KAVROO1 D_****************.zip
Unzip the downloaded file. A following file is created.
ONKAVROO1 D_************.of1
ONKAVROO1 D_************.of2
ONKAVROO1 D_************.of3
ONKAVROO1 D_************.of4
ONKAVROO1 D_************.of5
3. Copy it to the USB storage device. Be careful not to copy the zip file
4. Remove the USB storage device from your PC.
How to update (service mode)
Overwriting is also possible.
 1,Turn on the unit. It takes some time to start after you switch on the unit.
2.Select the USB input source.
3.Connect the USB storage device to USB port on the unit. Wait until Initializing of USBINET finishes.
4.Hold down [DISPLAY] button and then press [ONISTANDBY] button twice.
Main version will be displayed, and HYBRID STANDBY indicator will start to flash.
5.Press [RETURN] button. “NET -> ALL_D" will be displayed.
6.Select "USB -> ALL_D" by [PRESET(left/right)] cursors and [TUNING(up/down)] cursors, then press [ENTER] button, updating will begin.
7.Wait until update is completed. When the update ends, "Completed!" is displayed (if you leave it, it automatically turns standby mode. )
8.Press [ON/STANDBY] button, and the unit turns on.
9.Check the new FW version number.
<Note>
If the procedure might not be successful, please select "USB -> ALL_M”.
TROUBLESHOOTING
No Sound
No sound from connected player
# Chose input selector which is assigned to connected input terminal ?
# Isn't muting on ?
No sound from connected TV
# Chose wrong input selector ?
# Connect to this model's HDMI OUT terminal from TV by HDMI cable ?
# When TV supports ARC function, connect to his model's HDMI OUT terminal from TV's HDMI input terminal for ARC function ?
# When TV doesn't support ARC function, connect TV to this model with optical cable etc. ?
# Isn't muting on ?
No sound from some connected loudspeaker(s)
# No sound loudspeaker(s) config is enabled ?
No sound from all connected TV or B|u—ray player etc.
# After chose loudspeaker volume level setting, test tone is OK ?
No problem about above items
# Unplug power cord
After 10 seconds, connect power cord again
# Reset this model
NO Picture
In general
# Connection cable is bent , twisted or damaged ?
# Input is switched on TV ?
No picture from connected player by HDMI input terminal
# Chose input selector which is connected to player ?
# Listening mode is not Pure Audio ?
# Don't use HDMI—DVI adaptor. From personal computer ?
No picture from connected player by component video terminal
# Output to TV connected to component video out terminal from player's picture connected to the composite video input terminals ?
No problem about above items
# Unplug power cord
After 10 seconds connect the power cord again
Reset this model
No Power
In general
# Doesn't be connection cable bent, be it twisted and be it damaged?
There is time when indication on the front panel doesn't just light up.
# Please check the connecting cord of a DISPLAY PCB.
No problem about above items
# Unplug power cord
After 10 seconds, connect power cord again
# Reset this model
Read more »